The sorting process is (Fig. 1). After the slurry is fed into the tank body 3 (bottom tank) through the feeding tank 7, the ore is loosely fed into the feeding area of ​​the tank bottom under the action of the water flow to the mine spout pipe 6. . Due to the action of the magnetic field, the magnetic ore particles are magnetically aggregated to form a "magnet" or "magnetic flux", and are attracted to the magnetic pole by mechanical force such as gravity, and are attracted to the surface of the cylinder 1. Then turn up with the cylinder. Due to the alternating polarity of the magnetic system, magnetic agitation occurs in the ore particles to cause the mechanically mixed gangue to fall off, thereby improving the concentrate grade. The magnetic ore particles go to the weakest point along the edge of the magnetic system with the cylinder. Under the action of the flushing water jet discharged from the unloading water pipe 8, it is discharged into the concentrate tank. The non-magnetic or weak magnetic ore particles are discharged from the tailings hole of the bottom plate 9 into the tailings tube under the action of the slurry flowing rapidly in the tank.

Figure 1 Semi-reverse flow type permanent magnetic cylinder magnetic separator
1-cylinder; 2-magnetic system; 3-groove; 4-magnetic guide plate; 5-bracket; 6-spray pipe; 7-feeding tank;
8-unloading water pipe; 9-bottom plate; 10-magnetic declination adjustment device; 11-bracket

Cross Flow Cooling Tower

Since the height of the filling is close to the tower top, the water eliminator does not occupy much space, and the overall height of the cross-flow tower is small, which makes it relatively compact compared with counter flow type, and therefore lower air inlet speed and power consumption as well.


The cross-flow tower adopts a water distribution system that will let the water drop fall naturally by gravity. Thereby, water distribution holes are not easy to be blocked, as water distribution is even and maximizes the performance of the tower fillings. The inspection manhole also enables routinely maintenance without machine shutdown.


A lower part of the cross-flow tower filling is submerged in the water, so that the water flows through the surface of the filling and directly falls into the below tank, making low noise.


The cross-flow tower fan is located in the middle of the Cooling Tower, while the filling, on both sides of the tower. So the amount of splashing water is very small.

Cross Flow Cooling Tower,Cooling Tower Cools Water,Induced Draught Cooling Tower,Induced Draft Cross Flow Cooling Tower