All pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.
Fully autoclavable
The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121ºC, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparation. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic design,easy to press
- Digital displayÂ
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintainÂ
Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
SPECIFICATIONS
Single-channel Adjustable Volume Pipettes | ||||||
Volume Range | Increment | Test Volume(μl) | Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||
 |  |  | % | μl | % | μl |
0.1-2.5μl | 0.05μl | 2.5 | 2.50% | 0.0625 | 2.00% | 0.05 |
1.25 | 3.00% | 0.0375 | 3.00% | 0.0375 | ||
0.25 | 12.00% | 0.03 | 6.00% | 0.015 | ||
0.5-10μl | 0.1μl | 10 | 1.00% | 0.1 | 0.80% | 0.08 |
5 | 1.50% | 0.075 | 1.50% | 0.075 | ||
1 | 2.50% | 0.025 | 1.50% | 0.015 | ||
2-20μl | 0.5μl | 20 | 0.90% | 0.18 | 0.40% | 0.08 |
10 | 1.20% | 0.12 | 1.00% | 0.1 | ||
2 | 3.00% | 0.06 | 2.00% | 0.04 | ||
5-50μl | 0.5μl | 50 | 0.60% | 0.3 | 0.30% | 0.15 |
25 | 0.90% | 0.225 | 0.60% | 0.15 | ||
5 | 2.00% | 0.1 | 2.00% | 0.1 | ||
10-100μl | 1μl | 100 | 0.80% | 0.8 | 0.15% | 0.15 |
50 | 1.00% | 0.5 | 0.40% | 0.2 | ||
10 | 3.00% | 0.3 | 1.50% | 0.15 | ||
20-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 |
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||
20 | 3.00% | 0.6 | 1.00% | 0.2 | ||
50-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 |
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||
50 | 1.00% | 0.5 | 0.40% | 0.2 | ||
100-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 |
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||
100 | 2.00% | 2 | 0.70% | 0.7 | ||
200-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 |
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||
200 | 0.90% | 1.8 | 0.30% | 0.6 | ||
1000-5000μl | 50μl | 5000 | 0.50% | 25 | 0.15% | 7.5 |
2500 | 0.60% | 15 | 0.30% | 7.5 | ||
1000 | 0.70% | 7 | 0.30% | 3 | ||
2-10ml | 0.1ml | 10ml | 0.60% | 60 | 0.20% | 20 |
5ml | 1.20% | 60 | 0.30% | 15 | ||
2ml | 3.00% | 60 | 0.60% | 12 |
Â
8-channel Adjustable Volume Pipettes | ||||||||
Volume Range | Increment | Test Volume (μl) |
Maximume Permissible Systematic error   (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||||
 |  |  | % | μl | % | μl | ||
0.5-10μl | 0.1μl | 10 | 1.50% | 0.15 | 1.50% | 0.15 | ||
5 | 2.50% | 0.125 | 2.50% | 0.125 | ||||
1 | 4.00% | 0.04 | 4.00% | 0.04 | ||||
5-50μl | 0.5μl | 50 | 1.00% | 0.5 | 0.50% | 0.25 | ||
25 | 1.50% | 0.375 | 1.00% | 0.25 | ||||
5 | 3.00% | 0.15 | 2.00% | 0.1 | ||||
50-300μl | 5μl | 300 | 0.70% | 2.1 | 0.25% | 0.75 | ||
150 | 1.00% | 1.5 | 0.50% | 0.75 | ||||
50 | 1.50% | 0.75 | 0.80% | 0.4 | ||||
12-channel Adjustable Volume Pipettes | ||||||||
Volume Range | Increment | Test Volume(μl) | Maximume Permissible Systematic error   (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||||
 |  |  | % | μl | % | μl | ||
0.5-10μl | 0.1μl | 10 | 1.50% | 0.15 | 1.50% | 0.15 | ||
5 | 2.50% | 0.125 | 2.50% | 0.125 | ||||
1 | 4.00% | 0.04 | 4.00% | 0.04 | ||||
5-50μl | 0.5μl | 50 | 1.00% | 0.5 | 0.50% | 0.25 | ||
25 | 1.50% | 0.375 | 1.00% | 0.25 | ||||
5 | 3.00% | 0.15 | 2.00% | 0.1 | ||||
50-300μl | 5μl | 300 | 0.70% | 2.1 | 0.25% | 0.75 | ||
150 | 1.00% | 1.5 | 0.50% | 0.75 | ||||
50 | 1.50% | 0.75 | 0.80% | 0.4 | ||||
Fixed Volume Pipettes | ||||||||
Volume Range | Increment | Test Volume(μl) | Maximume Permissible Systematic error   (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||||
 |  |  | % | μl | % | μl | ||
5μl | - | 5μl | 1.3% | 0.065 | 1.2% | 0.06 | ||
10μl | - | 10μl | 0.8% | 0.08 | 0.8% | 0.08 | ||
20μl | - | 20μl | 0.6% | 0.12 | 0.5% | 0.1 | ||
25μl | - | 25μl | 0.5% | 0.125 | 0.3% | 0.075 | ||
50μl | - | 50μl | 0.5% | 0.25 | 0.3% | 0.15 | ||
100μl | - | 100μl | 0.5% | 0.5 | 0.3% | 0.3 | ||
200μl | - | 200μl | 0.4% | 0.8 | 0.2% | 0.4 | ||
250μl | -- | 250μl | 0.4% | 1.0 | 0.2% | 0.5 | ||
500μl | - | 500μl | 0.3% | 1.5 | 0.2% | 1.0 | ||
1000μl | - | 1000μl | 0.3% | 3.0 | 0.2% | 2.0 | ||
2000μl | - | 2000μl | 0.3% | 6.0 | 0.15% | 3.0 | ||
5000μl | - | 5000μl | 0.3% | 15 | 0.15% | 7.5 |
 DESCRIPTIONS
All pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.
Fully autoclavable
The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121ºC, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparation. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic design,easy to press
- Digital displayÂ
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintainÂ
Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
SPECIFICATIONS
Single-channel Adjustable Volume Pipettes | ||||||
Volume Range | Increment | Test Volume(μl) | Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||
 |  |  | % | μl | % | μl |
0.1-2.5μl | 0.05μl | 2.5 | 2.50% | 0.0625 | 2.00% | 0.05 |
1.25 | 3.00% | 0.0375 | 3.00% | 0.0375 | ||
0.25 | 12.00% | 0.03 | 6.00% | 0.015 | ||
0.5-10μl | 0.1μl | 10 | 1.00% | 0.1 | 0.80% | 0.08 |
5 | 1.50% | 0.075 | 1.50% | 0.075 | ||
1 | 2.50% | 0.025 | 1.50% | 0.015 | ||
2-20μl | 0.5μl | 20 | 0.90% | 0.18 | 0.40% | 0.08 |
10 | 1.20% | 0.12 | 1.00% | 0.1 | ||
2 | 3.00% | 0.06 | 2.00% | 0.04 | ||
5-50μl | 0.5μl | 50 | 0.60% | 0.3 | 0.30% | 0.15 |
25 | 0.90% | 0.225 | 0.60% | 0.15 | ||
5 | 2.00% | 0.1 | 2.00% | 0.1 | ||
10-100μl | 1μl | 100 | 0.80% | 0.8 | 0.15% | 0.15 |
50 | 1.00% | 0.5 | 0.40% | 0.2 | ||
10 | 3.00% | 0.3 | 1.50% | 0.15 | ||
20-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 |
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||
20 | 3.00% | 0.6 | 1.00% | 0.2 | ||
50-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 |
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||
50 | 1.00% | 0.5 | 0.40% | 0.2 | ||
100-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 |
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||
100 | 2.00% | 2 | 0.70% | 0.7 | ||
200-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 |
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||
200 | 0.90% | 1.8 | 0.30% | 0.6 | ||
1000-5000μl | 50μl | 5000 | 0.50% | 25 | 0.15% | 7.5 |
2500 | 0.60% | 15 | 0.30% | 7.5 | ||
1000 | 0.70% | 7 | 0.30% | 3 | ||
2-10ml | 0.1ml | 10ml | 0.60% | 60 | 0.20% | 20 |
5ml | 1.20% | 60 | 0.30% | 15 | ||
2ml | 3.00% | 60 | 0.60% | 12 |
Â
8-channel Adjustable Volume Pipettes | ||||||||
Volume Range | Increment | Test Volume (μl) |
Maximume Permissible Systematic error   (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||||
 |  |  | % | μl | % | μl | ||
0.5-10μl | 0.1μl | 10 | 1.50% | 0.15 | 1.50% | 0.15 | ||
5 | 2.50% | 0.125 | 2.50% | 0.125 | ||||
1 | 4.00% | 0.04 | 4.00% | 0.04 | ||||
5-50μl | 0.5μl | 50 | 1.00% | 0.5 | 0.50% | 0.25 | ||
25 | 1.50% | 0.375 | 1.00% | 0.25 | ||||
5 | 3.00% | 0.15 | 2.00% | 0.1 | ||||
50-300μl | 5μl | 300 | 0.70% | 2.1 | 0.25% | 0.75 | ||
150 | 1.00% | 1.5 | 0.50% | 0.75 | ||||
50 | 1.50% | 0.75 | 0.80% | 0.4 | ||||
12-channel Adjustable Volume Pipettes | ||||||||
Volume Range | Increment | Test Volume(μl) | Maximume Permissible Systematic error   (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||||
 |  |  | % | μl | % | μl | ||
0.5-10μl | 0.1μl | 10 | 1.50% | 0.15 | 1.50% | 0.15 | ||
5 | 2.50% | 0.125 | 2.50% | 0.125 | ||||
1 | 4.00% | 0.04 | 4.00% | 0.04 | ||||
5-50μl | 0.5μl | 50 | 1.00% | 0.5 | 0.50% | 0.25 | ||
25 | 1.50% | 0.375 | 1.00% | 0.25 | ||||
5 | 3.00% | 0.15 | 2.00% | 0.1 | ||||
50-300μl | 5μl | 300 | 0.70% | 2.1 | 0.25% | 0.75 | ||
150 | 1.00% | 1.5 | 0.50% | 0.75 | ||||
50 | 1.50% | 0.75 | 0.80% | 0.4 | ||||
Fixed Volume Pipettes | ||||||||
Volume Range | Increment | Test Volume(μl) | Maximume Permissible Systematic error   (Inaccuracy) |
Maximume Permissible Random error   (Inaccuracy) |
||||
 |  |  | % | μl | % | μl | ||
5μl | - | 5μl | 1.3% | 0.065 | 1.2% | 0.06 | ||
10μl | - | 10μl | 0.8% | 0.08 | 0.8% | 0.08 | ||
20μl | - | 20μl | 0.6% | 0.12 | 0.5% | 0.1 | ||
25μl | - | 25μl | 0.5% | 0.125 | 0.3% | 0.075 | ||
50μl | - | 50μl | 0.5% | 0.25 | 0.3% | 0.15 | ||
100μl | - | 100μl | 0.5% | 0.5 | 0.3% | 0.3 | ||
200μl | - | 200μl | 0.4% | 0.8 | 0.2% | 0.4 | ||
250μl | -- | 250μl | 0.4% | 1.0 | 0.2% | 0.5 | ||
500μl | - | 500μl | 0.3% | 1.5 | 0.2% | 1.0 | ||
1000μl | - | 1000μl | 0.3% | 3.0 | 0.2% | 2.0 | ||
2000μl | - | 2000μl | 0.3% | 6.0 | 0.15% | 3.0 | ||
5000μl | - | 5000μl | 0.3% | 15 | 0.15% | 7.5 |
Â
Hywell Machinery company proffesional to design and manufacture the Granules Mixing Machine, 3D Mixer that include EYH Two Dimensional Mixing Machine/ two dimensional mixer , V type mixing machine, Rocking mixing machine , SYH Three Dimensional Mixing Machine and V Type High Efficient Mixing Machine. welcome to contact us and we will offer competitive price !
Granules Mixing Machine is new kind of equipment with high efficiency and simple structure which was improved by our company. it made powder mixed. this big mixer machine is easy to clean up, fully meeting "GMP" .The granules mixing machine is suitable for granules powder in pharmaceutical industry, chemical, foodstuff, dyestuff, agrochemical industry etc. Structure simply, operation convenience, high efficience. And the EYH Two Dimensional Mixing Machine , YYH Drum Powder Mixing Machine ,SYH 3D Mixing Machine also approved the CE.
3D Powder Mixer,Granules Mixing Machine,V Type Mixing Machine,Two Dimensional Mixer,Bin Powder Blender
Changzhou ErBang Drying Equipment Co., Ltd. , https://www.hywell-dryers.com